10MHz frequency source
Possible sources
All sources exist in ResLab.
- Passive Hydrogen Maser
- OCXO
- OXCO 5 MHz
- OXCO 10 MHz (broken)
- Rubidium Frequency Standard
- GPS receiver
- Marconi Synthesizer, Model: 2024
- Andere Syntheziszer
- Selfmade distributor [Klaus]
- K+K distributor (not for high quality distribution)
- HighTec Fiber ???
- CSAC Chip für stabile 10MHz Referenz
Current Setup [30.05.2017]
Future Setup
- Ansprechpartner für Löcher in der Uni: Miehlbradt, Marion (Tel.: 2258)
- Schadstoffuntersuchungsbericht: Negativ auf Aspest von Firma Wessling!
Experiment Ansprechperson Experiment Ansprechperson Kabelverlegeung | Raumnummer | Number of cables [new = , old = ] Mean cable Lab cable | Number of distributors (Number of outputs) | Cable length + “Lab cable Length” [m] | Holes [Number, size, place] | Notes |
---|---|---|---|---|---|---|
ResLab S. Sauer S. Sauer | D215 | 2 [] 16 [] | 2 (16) | 1 (OXCO-Mean distributor) + 1 (Mean distributor - Reslab distributor) + 16*5 | 1, Ø=?, Reslab-Q-Port | - |
Atom-Lab-Mg S. Sauer W. Friesen | D320 | 2 [] 8 [] | 1 (16) | 2*[ 25(Reslab - Mg-Lab) + 10(Mg-Lab)] + 8*5 | 1, Ø=5-10cm, Q-Port-Atom-Lab-Mg | - |
KRb J. Peise A. Igel | E311 | 1 + ? [] | 1 (16) | 25(Reslab - Mg-Lab) + 20(Mg-Lab) + 60(Mg-Lab-KRB) | - | * KRB_10MHz_Kabel_08_2017 * Die Durchführungen sind alle groß genug, nur auf höhe des Elektroniklabors liegen die Kabel in der Nähe von Heizungsrohren. * Im Flur befindet sich ein offener Kabelkanal. |
QAI,EPR J. Peise C. Pür | D313 → D315 | 1 + ? [] | 1 (16) | 25 (Reslab - Mg-Lab) + 20(Mg-Lab) + 25(Mg-Lab-QAI) + 25(QAI-EPR) | - | - |
ATLAS H. Albers H. Albers | D330 | 1 + ? [] | 1 (16) | 25(Reslab - Mg-Lab) + 25(Mg-Lab) + 50 (Mg-Lab-ATLAS) + 5(ATLAS-Lab) | ?, Ø=10cm, ? | * ATLAS_10MHz_Habel_08_2017 * Gibt keine Information wie es über den Seminarraum verlegt ist → Neue Löcher bohren oder zusätzlicher Durchgang zu VLBAI |
VLBAI E. Wodey ? | D323 | 1 [] | 1 (16) | 25(Reslab - Mg-Lab) + 25(Mg-Lab) + 20 (Mg-Lab-VLBAI) + 5 (VLBAI) | - | - |
Quantengravi J. Mathias ? | D323 | 1 [] | 1 (16) | 25(Reslab - Mg-Lab) + 25(Mg-Lab) + 20 (Mg-Lab-VLBAI) + 5 (VLBAI) | - | - |
AG S.& C. Ospelkaus Mirko Sierke S. Grondwoski | E304A → E104A | 1 [] 2 [] | 2 (min. 8) | 25(Reslab - Mg-Lab) + 25 (Mg-Lab) + 100 (Mg-Lab - E-Trakt = vorhanden!) + E-Trakt | - | *AG_Ospelkaus_10MHz_Habel_08_2017 * Das vorhandene Kabel ist 100 Meter lang und hat bei 10 MHz eine Dämpfung von etwa 4,3 dB. * Kabelnanfang im Mg-Labor ist mit “CW Tiemann” und das Ende im E-Trakt ist mit “MG ERT” beschriftet |
Q-Port S. Bode ? | 1 [] | - | - | - | Vorhandene Kabel ist verlegt, muss noch getestet werden | |
Lasus Thejs ? | D220 | 1 [] | - | - | - | * Vorhandene Kabel ist verlegt, Aircell 7, muss noch getestet werden * Sein vorhandener Verteiler ist ein SRS FS710 |
Maius D. Becker | keine Antwort | keine Antwort | - | - | - | |
AG Morgner B. Kreipe | 0 | 0 | - | - | - | |
Gesamt | 7 (16) 2 (min 8) | 622 |
To Do
1)
FSWP-8 refernced to Maser
FSWP-8 running 1 day ahead of measurement
Measure: 100mHz-10MHz PN Rb-clock
- “GPS →” Rb-10Mhz [right Output] → BNC cable → BNC-I-connector → BNC-SMA-connecotor → long cable → PNA
- Channel J1 and J2: OCXO → short cable → SMA-I-connector → long cable → PNA
Measure: -"- -"- OCXO 5MHzx2 (passive)
- J1 → short cable → SMA-BNC-connector → TP [6MHz] → long cable → PNA
- J1 → short cable → SMA-BNC-connector → TP [6MHz] → Doubler [FD-2+] → BNC-SMA-connector → long cable → PNA
- J1 → short cable → SMA-BNC-connector → TP [6MHz] → Doubler [FD-2+] → BNC-SMA-connector → BP [SBP-10.7+] → long cable → PNA
- J1 → short cable → SMA-BNC-connector → TP [6MHz] → Doubler [FD-2+] → BNC-SMA-connector → BP [SBP-10.7+] → BNC-SMA-connector → Att. [10dB] → BNC-SMA-connector → long cable → PNA
- Overall setup: J1 → short cable → SMA-BNC-connector → TP [6MHz] → Doubler [FD-2+] → BNC-SMA-connector → BP [SBP-10.7+] → BNC-SMA-connector → Att. [10dB] → short BNC-cable → Amplifier [ZFL-500LN-BNC+] → LP [BLP-15] → Att. [20dB] → Att. [3dB] → BNC-SMA-connector → long SMA cable → PNA
Measure: -"- -"- OCXO 5MHzx2 (DDS?)
- Currently not possible.
2)
Propagate K+K manuals
3)
Repair K+K box
4)
Compare PN Marconi vs. ampfiers (which?)
5)
Compare Specs Timetech & Spectra dynamics -> (PN, Channel/CHannel isolation, Groundloops, min input power @ 10MHz)
Distibution
- Timetech distributor:
- Gibt es für Eco (Isolation: 120dB bei 10MHz / only BNC) und High Performance (Isolation: 150dB / only SMA)
- Spectra dynamics distributor: HPDA-15RMi Datasheet_HPDA-15RMi
6)
HiTec: where is to 10MHz RF
7)
Cable, Connector choice
Which cables?
- Best choise (cost-effectiveness) < 150 MHz: RG223 - DatasheetRG223 - conrad
- Aircell 5 for > 100 MHz
- Low attenuation for higher frequecies (also for 10MHz compared to RG223)
- Kai-Martin-Quelle: Aircell 5 - ssb
- For high frequencies <10 GHz: accuphasebrochure.pdf
- Testing cable:
- Offenes Ende vermessen, dann sollte es Hochohmig sein
- Auf einer Seite mit 50 Ohm verbinden und vermessen: 50 Ohm+Kabelwiderstand (<3-4 Ohm ist ok)
- Wenn der Kabelwiderstand höher ist, dann wurden vermutlich beim Crimpen (Luft-)Übergangswiderstände erzeugt
Connectors typ
- BNC-Connector, male crimp: Part No. 7721 von SSB-electronics.com
- SMA-Connector, crimp male: Part No. 7750 von SSB-electronics.com
8)
More cables for counter RF-Signals in the resLab?
9)
Which mains filter and cold-device plug?
- PTB is using this model: 521062-21 HARTU
- Datasheet: 521062-21 HARTU
E-Mail-Antwort der Firma Hartu zu dem Model 521062-21 HARTU es handelt sich bei 521062-21 um ein 50/60 Hz Netzfilter. Die Sicherheitsnormen schreiben Luft- und Kriechstrecken und eine 100% Hochspannungsprüfung vor. Die Isolation der eingebauten Stromkompensierten Drossel wird über einen Trennsteg aus Kunststoff zwischen den Phasen und die Kernisolation sichergestellt. Es wird eine Hochspannungsprüfung zwischen den Phasen von 1,41kV/50Hz/2s durchgeführt. Gegen Erde wird mit 2KV/50Hz/2s geprüft.
Daten über die Isolation bei anderen Frequenzen liegen nicht vor.
- I contacted Schürter to find a mains filter with high isolation at low frequencies and low current (1A):
- Model: 5123 G-STECKER FILTER 1A, Konfigurations-Code: 5123.0000.0
- Datasheet: 5123 Schürter
Mor isolation between ports?
- Zur Vermeidung von Masseschleifen
- Use: FTB-1-1*A26+
- Datasheet: FTB-1-1*A26+
- Aufbau:
- Transformator in den jeweiligen Nutzerlaboren einbauen, damit das Kabel noch geschirmt ist und nicht hoch-Ohmig
- Kabel kommend vom ResLab an Isolierter Port des Transformators
- Transformator-Gehäuse irgendwo dranschrauben
- Gehäuse hat Masse des Nutzerlabors
OCXO
- Frequency double, how?
- Read Phase-Lock-Loop page
Filters
- 5MHz
- 10MHz