Line 38: Line 38:
 ===== Measured Data ===== ===== Measured Data =====
 The {{ :groups:mg:private:resonatoren:photodiodeetienne:messwerte.zip |traces}} of the amplitude and phase were measured. The {{ :groups:mg:private:resonatoren:photodiodeetienne:messwerte.zip |traces}} of the amplitude and phase were measured.
-  * A <fc #ff0000>RIGOL Network Analyzer</fc> was used to gather that {{ :groups:mg:private:resonatoren:photodiodeetienne:messwerte.zip |data}} from the AC output +  * A <color #ff0000>RIGOL Network Analyzer</color> was used to gather that {{ :groups:mg:private:resonatoren:photodiodeetienne:messwerte.zip |data}} from the AC output 
-  * A 9V test-laser with a modulation of <fc #ff0000>[-10dB @ 100MHz]</fc> was used in this experimental setup +  * A 9V test-laser with a modulation of -10dB @ 100MHz was used in this experimental setup 
-  * The traces of the diodes were fitted with {{ :groups:mg:private:resonatoren:photodiodeetienne:gaussian_fit.py |Python}}+  * The traces of the diodes were fitted in {{ :groups:mg:private:resonatoren:photodiodeetienne:gaussian_fit.py |Python}}
  
 ==== The results: ==== ==== The results: ====
-{{:groups:mg:private:resonatoren:photodiodeetienne:fit1.png |FWHM [Diode 1]: 271750.86662876786Hz}} +^ Diode^ Resonance frequency [MHz]  ^ Peak to 15MHz Ratio [dB]  ^ P14R [dB] ^ P17R [dB] ^ P18R [dB] ^ FWHM with Gauß-Fit [kHz]     ^ Phase #1     ^ Comment 
-{{ :groups:mg:private:resonatoren:photodiodeetienne:fit2.png|FWHM [Diode 2]: 270984.2391765082Hz}}+|  1   | 16.11 [+/- 0.015]          | 8.65                      | 13.71     | 6.99      | 12.44     | 271.75                                    |          | 
 +|  2   | 16.14 [+/- 0.01]           | 8.92                      | 13.46     | 6.53      | 11.34     | 270.98                                    |          | 
 +|  3   | 16.13 [+/- 0.01]           | 9.17                      | 14.75     | 6.66      | 12.13     | 271.45                                    |          | 
 +|  4   | 16.16 [+/- 0.01]           | 9.39                      | 14.81     | 6.5       | 12.09     | 269.72                                    |          | 
 + 
 +#1  
 +<color #ff00ff>Was bedeutet P17 etc?</color> 
 +#2 <color #00ff00>Peak to 17MHz Ratio [Name sollte besser noch geändert werden]</color> 
 +  * X = MAx dazu Y Wert = Peak hight over .. 
 +  * <color #ff0000>Es feht der Fehler von der Linienbreite und des Max Peaks</color> 
 +  * Höhe des Resonanz-Peaks über Rauschen 
 + 
 +{{:groups:mg:private:resonatoren:photodiodeetienne:fit1.png |FWHM [Diode 1]: 271750.86662876786Hz}}\\ 
 +{{:groups:mg:private:resonatoren:photodiodeetienne:fit2.png|FWHM [Diode 2]: 270984.2391765082Hz}}\\ 
 +{{:groups:mg:private:resonatoren:photodiodeetienne:fit3.png |FWHM [Diode 3]: 271450.8282159102Hz}}\\ 
 +{{:groups:mg:private:resonatoren:photodiodeetienne:fit4.png|FWHM [Diode 4]: 269724.22527546244Hz}}\\ 
 + 
 + 
 +===== Wechselwirkung (WW) EOM und PD Nr.4 ===== 
 + 
 +Spektrometer Rhode&Schwarz 
 +RBW: 100Hz 
 +VBW: 10Hz 
 +SWT: 30s  
 +Ref: 0dBm 
 +Att: 10dB 
 + 
 +{{:groups:mg:private:resonatoren:photodiodeetienne:ww_pd_eom_wdh.messung_3.png?400|}}
  
-{{:groups:mg:private:resonatoren:photodiodeetienne:fit3.png |FWHM [Diode 3]: 271450.8282159102Hz}} 
-{{ :groups:mg:private:resonatoren:photodiodeetienne:fit4.png|FWHM [Diode 4]: 269724.22527546244Hz}}