meta data for this page
  •  

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
groups:mg:project_ptb-cavity:vacuum:electronics_inside_the_vacuum [2017/05/09 11:12] ssauergroups:mg:project_ptb-cavity:vacuum:electronics_inside_the_vacuum [2017/11/01 14:35] (current) ssauer
Line 1: Line 1:
 =====Electronic parts inside the vacuum and accessories===== =====Electronic parts inside the vacuum and accessories=====
  
 +===== Selfmade Crimp-Connection-Isolation =====
 +Company: IQ Workshop
  
 +  * Material: Peek
 +  * {{ :groups:mg:project_ptb-cavity:vacuum:crimpkontakt_isolierbuchse_2d.pdf |Crimp-Connection-Isolation_Big}}
 +  * {{ :groups:mg:project_ptb-cavity:vacuum:crimpkontakt_isolierbuchse_4_anschluesse_2d.pdf |Crimp-Connection-Isolation_Small}}
  
-===== Sub-D stuff =====+ 
 +===== Sub-D connections =====
 Company: Allectra Company: Allectra
  
 ==Sub-D cable===  ==Sub-D cable=== 
-  * 37FXRR-500  +  * Part-Code: 380-37FXRR-500  
-  * Capton +  * Length: 0.5m 
 +  * Capton isolated 
 + 
 +  * Part-Code: 380S-D09FXP0,75-500 
 +  * Length: 0.5m 
 +  * Capton isolated 
 +
  
 ==Sub-D Feedthrough== ==Sub-D Feedthrough==
 +  * Part-Code for Sub-D37: 210S-D37-120x57-PTB
 +  * Part-Code for Sub-D9: 210S-D09-93x57-PTB
   * Peek   * Peek
  
-===== Cable stuff =====+===== Cables =====
 Company: Allectra Company: Allectra
 ==Crimp pins for Sub-D female== ==Crimp pins for Sub-D female==
Line 38: Line 52:
   * Länge min.: 300mm   * Länge min.: 300mm
   * Durcschlagfestigkeit typ.: 10KV   * Durcschlagfestigkeit typ.: 10KV
 +
 +==Heat-shrink tubing==
 +  * Typ: 316-SHRINK-32
 +  * UHV Schrumpfschlauch (auf PTFE Basis) 
 +  * Durchmesser: 3.2mm 
 +  * nach Schrumpfung: min. 1.0mm
 +  * Schrumpftemperatur: >350°C
 +  * Länge: 50cm
 +  * {{ :groups:mg:project_ptb-cavity:vacuum:316-shrink.pdf |Datasheet_Heat-shrink}}
 +  * {{ :groups:mg:project_ptb-cavity:vacuum:allectra_katalog_shrink.pdf |katalog_shrink_capton tube}}
 +
 +===Capton wire===
 +
 +  * Typ: 311-KAP-040-5M (http://shop.allectra.eu/product_info.php/products_id/1656/adminpreview/true/osCsid/723b178f2d3aa4c28c44a6437b702759)
 +  * UHV-tauglich
 +  * massive Kupferleiter
 +  * Kaptonband-isoliert
 +  * Kupferleiter: Kabeldurchmesser 0.40mm
 +  * AWG 26
  
 ===Capton wire=== ===Capton wire===
Line 58: Line 91:
   * Max. Gesamt-Ø 0.98 mm   * Max. Gesamt-Ø 0.98 mm
   * Leiterquerschnitt 0.34 mm² (AWG 22)   * Leiterquerschnitt 0.34 mm² (AWG 22)
- 
- 
  
 =====Peltier element ==== =====Peltier element ====