Line 1: Line 1:
-====== HMaser ====== +====== HMaser (PHM-H7) ======
- +
-  * Maser-Software [[.:Monitor VCH-1006|Monitor VCH-1006]] installed on ResLab-Maser-Laptop +
-  * Maser & Software work at IQ  +
-  * Maser has a AC (rechargeable battery) and DC (Schuko) port +
-  * Maser Measurement by PTB: {{ :groups:mg:h-maser_stability.pdf |}}\\ {{:groups:mg:reslab:labbook:2016-09:maser_data.jpg?300|}} +
- +
-  * borrowed from PTB:\\ {{:groups:mg:reslab:labbook:2016-09:ausleihlist.jpg?300|}} +
-  * Maser manual: {{ :groups:mg:reslab:labbook:2016-09:h-maser_maintenance_and_service_manual.pdf |}} +
-  * Maser software manual: {{ :groups:mg:reslab:labbook:2016-09:h-maser_program_monitor_vch-1006.pdf |}}+
  
 === Information === === Information ===
Line 17: Line 8:
   * Niemals die Temperatur des Masers verändern!   * Niemals die Temperatur des Masers verändern!
   * **NICHTS AM MASER einstellen!**   * **NICHTS AM MASER einstellen!**
 +  * Regelmäßig (einmal im Jahr) die "history.dat" Dateien Herrn Bauch zukommen lassen, dieser sendet sie weiter nach Russland und die checken dann den PHM
  
 +  * borrowed from PTB:\\ {{:groups:mg:reslab:labbook:2016-09:ausleihlist.jpg?300|}}
 +  * Maser-Software [[.:Monitor VCH-1006|Monitor VCH-1006]] installed on ResLab-Maser-Laptop
 +  * Maser has a AC (rechargeable battery) and DC (Schuko) port
 +  * Maser manual: {{ :groups:mg:reslab:labbook:2016-09:h-maser_maintenance_and_service_manual.pdf |}}
 +  * Maser software manual: {{ :groups:mg:reslab:labbook:2016-09:h-maser_program_monitor_vch-1006.pdf |}}
 +
 +=== 12.2020 ===
 +Qstat und D2h sind anders zu den anderen Werten zuvor.\\
 +{{:groups:mg:private:resonatoren:maser:maser_17.12.2020.png?400|}}
 +
 +=== 02.2020 ===
 +IG Pump Wert ist blau (!?!)\\
 +{{:groups:mg:private:resonatoren:maser:hmaser02_2020.png?400|}}
 +
 +
 +=== 2019 ===
 +Der Wert der blau ist, ist weil der interne Akku nicht mehr geladen werden kann. -> ist Herrn Bauch bekannt\\
 +{{:groups:mg:private:resonatoren:maser:vch-1006_181119.jpg?400|}}
 +=== 2018 ===
 +  * Hannover -> PTB\\
 +{{:groups:mg:private:resonatoren:maser:img_0468.jpg?300|}}
 +=== 2016 ===
 +  * Maser Measurement by PTB: {{ :groups:mg:h-maser_stability.pdf |}}\\ {{:groups:mg:reslab:labbook:2016-09:maser_data.jpg?300|}}
 +  * Maser & Software work at IQ 
   * PTB -> Hannover\\   * PTB -> Hannover\\
 {{:groups:mg:reslab:labbook:2016-09:img_1503.jpg?300|}} {{:groups:mg:reslab:labbook:2016-09:img_1503.jpg?300|}}