meta data for this page
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
groups:mg:private:resonatoren:k_k_counter:start [2020/03/12 10:04] – [Bedienung der Version "FXX_App 1.4" mit E-Mail Warnung] ssauer | groups:mg:private:resonatoren:k_k_counter:start [2024/03/20 09:37] (current) – Admin: Syntax-Update (Migration from deprecated "fontcolor" plugin to "color" plugin) klaus | ||
---|---|---|---|
Line 38: | Line 38: | ||
===== Software ===== | ===== Software ===== | ||
- | ==== Bedienung der Version " | + | ==== Bedienung der Version " |
* Software Link: \\AFS\.iqo.uni-hannover.de\projects\magnesium\Software\K+K Zähler mit E-Mail Meldung\FXX App Ver_1_4.zip | * Software Link: \\AFS\.iqo.uni-hannover.de\projects\magnesium\Software\K+K Zähler mit E-Mail Meldung\FXX App Ver_1_4.zip | ||
- | * Advantags: | + | * Vorteile: |
- Überwachung von Eingangsfrequenzen und Referenztakt mit einstellbarer Fehlertoleranz | - Überwachung von Eingangsfrequenzen und Referenztakt mit einstellbarer Fehlertoleranz | ||
- Benachrichtigung per Email | - Benachrichtigung per Email | ||
Line 56: | Line 56: | ||
* E-Mail Notification: | * E-Mail Notification: | ||
* E-mail: 10mhz@iqo.uni-hannover.de | * E-mail: 10mhz@iqo.uni-hannover.de | ||
- | * password: ask Steffen Sauer | + | * Notify: Always |
+ | * Source: A | ||
+ | * Classes: | ||
+ | * All Errors, Warnings | ||
+ | * All Infos | ||
+ | * Config Email Server: | ||
* SMTP Host: mailgate.uni-hannover.de (https:// | * SMTP Host: mailgate.uni-hannover.de (https:// | ||
- | * Port: 25 | + | * Port: 587 |
+ | * Account name: 10mhz@iqo.uni-hannover.de | ||
+ | * password: ask Steffen Sauer | ||
+ | * Email Sender: 10mhz@iqo.uni-hannover.de | ||
+ | * Clock Warnings: | ||
+ | * general: | ||
+ | * Min. count before warning: 1 | ||
+ | * Next warning after **0** minutes | ||
+ | * Add warnings to log files: no | ||
+ | * Channel 9: HMaser | ||
+ | * Nominal frequency: 10, | ||
+ | * Margin: 0.000050 Hz | ||
+ | * Warning Channel : Check | ||
+ | * Warning reference Clock: Check | ||
+ | * Channel 10: Rb clock | ||
+ | * Nominal frequency: 10, | ||
+ | * Margin: 0.001 Hz | ||
+ | * Warning Channel : Check | ||
+ | * Warning reference Clock: Check | ||
+ | |||
==== Bedienung der Version "K+K FXE 18-05-08" | ==== Bedienung der Version "K+K FXE 18-05-08" | ||
Line 105: | Line 130: | ||
* Unordered List ItemDifference between π- and Λ-measurement: | * Unordered List ItemDifference between π- and Λ-measurement: | ||
* π-measurement = // | * π-measurement = // | ||
- | * Λ-measurement = //Phase Average// <fc # | + | * Λ-measurement = //Phase Average// <color # |
Line 119: | Line 144: | ||
| | ||
- | **b) Averaged phase report mode <fc # | + | **b) Averaged phase report mode <color # |
The on-board microprocessor calculates the average of all raw measurements taken during the report interval and reports to the PC at the end of the interval. All raw measurements contribute to the reported result. This helps to reduce measurement noise. Results reported (@ interval 1s) will be | The on-board microprocessor calculates the average of all raw measurements taken during the report interval and reports to the PC at the end of the interval. All raw measurements contribute to the reported result. This helps to reduce measurement noise. Results reported (@ interval 1s) will be | ||
| | ||
Line 167: | Line 192: | ||
=== Freq. Conv. = Frequency Conversion === | === Freq. Conv. = Frequency Conversion === | ||
- | * **off** <fc # | + | * **off** <color # |
- Ist eine Spezialfallanwendung, | - Ist eine Spezialfallanwendung, | ||
Line 174: | Line 199: | ||
* **W/N** für Windows | * **W/N** für Windows | ||
* **"," | * **"," | ||
- | * **" | + | * **" |
=== Graph === | === Graph === |