groups:mg:private:meetingnotes:2020-11:meetingnotes-2020-11-23 [2020/11/23 12:01] – created klaus | groups:mg:private:meetingnotes:2020-11:meetingnotes-2020-11-23 [2020/11/23 12:03] (current) – klaus | ||
---|---|---|---|
Line 8: | Line 8: | ||
* 1.3 W @ f=100mm | * 1.3 W @ f=100mm | ||
* Outcoupling beam cant kept symmetrically | * Outcoupling beam cant kept symmetrically | ||
- | * Probably first collimation lense not perfectly collimating -> You can't get the beam symmetrical with TODO | + | * Probably first collimation lense not perfectly collimating -> You can't get the beam symmetrical |
+ | * It is crucial, to have the beam well collimated, since you can't compensate for an astigmatism with the prism. | ||
* Build a spare laser for L4 but in Littrow configuration | * Build a spare laser for L4 but in Littrow configuration | ||
* SWAP experiments | * SWAP experiments |